Diesel Power Generating Sets

Service is the most important department in the organization with factory trained engineers and technicians supported by Mobile Service Vans, latest diagnosis software, hi-tech tools & equipment’s. 24 hrs. hotline numbers are allotted for all your service requirements.Service is the most important department in the organization with factory trained engineers and technicians supported by Mobile Service Vans, latest diagnosis software, hi-tech tools & equipment’s. 24 hrs. hotline numbers are allotted for all your service requirements.Service is the most important department in the organization with factory trained engineers and technicians supported by Mobile Service Vans, latest diagnosis software, hi-tech tools & equipment’s. 24 hrs. hotline numbers are allotted for all your service requirements.

Quality driven Generators from Spain

150 kVA to 630 kVA
Genset Model

Generator Set
Prime (kVA) 

Output 50 Hz
Standby (kVA)
Mechanical Structure Engine Model Alternator Brand Dimension (mm) Lx W x H Weight (kg) Acoustic Pressure Fuel Tank Capacity(L) Fuel Consumption 75 % (L/H)
IV-165
150 160 Soundproofed TAD 731 GE Mecc-Alte 2950x1100x1760 2150 67 220 26
IV-220 200 220 Soundproofed TAD 733 GE Mecc-Alte 3600x1350x2040 2980 67 360 34
IV-275 250 275 Soundproofed TAD 734 GE Mecc-Alte 3600x1350x2040 3018 67 360 42
IV-330 300 330 Soundproofed TAD 1341 GE Stamford 4200x1600x2145 4200 67 534 51
IV-385 350 385 Soundproofed TAD 1342 GE Stamford 4200x1600x2145 4360 67 534 53
IV-440 400 440 Soundproofed TAD 1344 GE Stamford 4200x1600x2145 4600 67 534 63
IV-500 450 500 Soundproofed TAD 1345 GE Stamford 4200x1600x2145 4660 68 534 69
IV-550 500 550 Soundproofed TAD 1641 GE Stamford 4860x2060x2630 5940 68 1000 77
IV-700 630 700 Soundproofed TWD 1643 GE Stamford 4860x2060x2630 6660 68 1000 89

Please click the model number to download the spec sheet for each model

400 kVA to 665 kVA
Genset Model

Generator Set
Prime (kVA) 

Output 50 Hz
Standby (kVA)
Mechanical Structure Engine Model Alternator Brand Dimension (mm) Lx W x H Weight (kg) Acoustic Pressure Fuel Tank Capacity(L) Fuel Consumption 75 % (L/H)
IV-440
400 440
Soundproofed 2206A-E13TAG3 Stamford 4200x1600x2245 4580 67 150
150
IV-550 400
440
Soundproofed 2206A-E13TAG3 Stamford 4200x1600x2245 4580
67 150
150
IP-680 400
440
Soundproofed 2206A-E13TAG3 Stamford 2206A-E13TAG3 4580 67 150
150
IP-720 400
440
Soundproofed 2206A-E13TAG3 Stamford 4200x1600x2245 4580 67 150
150

Please click the model number to download the spec sheet for each model

30 kVA to 200 kVA
Genset Model

Generator Set
Prime (kVA) 

Output 50 Hz
Standby (kVA)
Mechanical Structure Engine Model Alternator Brand Dimension (mm) Lx W x H Weight (kg) Acoustic Pressure Fuel Tank Capacity(L) Fuel Consumption 75 % (L/H)
II-033
30 33 
Soundproofed F32AM1A Mecc-Alte 2000x950x1353 980
67 85
6.5
II-044 40 
44 
Soundproofed F32SM1A Mecc-Alte 2500x1100x1455 1230
67 85
8.5 
II-055 50 55 
Soundproofed N45AM2 Mecc-Alte 2500x1100x1455 1260
67 85
9.6
II-055 60
66 
Soundproofed N45SM1A Mecc-Alte 2950x1100x1760 1298
67 85
10.2
II-083 75 83 Soundproofed N45SM2A Mecc-Alte 2950x1100x1760 1540 67 220 12.7
II-090 80 90 Soundproofed N45SM3 Mecc-Alte 2950x1100x1760 1540 67 220 15.4
II-110 100 110 Soundproofed N45TM2A Mecc-Alte 2950x1100x1760 1900 67 220 16.2
II-135 125 135 Soundproofed N45TM3 Mecc-Alte 2950x1100x1760 1910 67 220 21.2
II-175 160 175 Soundproofed N67TM4 Mecc-Alte 2950x1100x1760 1960 67 220 29.4
II-190 170 190 Soundproofed N67TM4 Mecc-Alte 2950x1100x1760 1980 67 220 29.4
II-220 200 220 Soundproofed N67TE2A Mecc-Alte 3600x1350x2040 2580 67 360 35.7